@JoshLafleur

Line 141:142 of 'BMS.c' in bmsb improlerly checks that voltage and timeout. Logic should be
(validmc & validmcvolts) | (valid chrg & valid chgvolts). Presently, a old reported voltage which is above the precharge ratio with the other message sending a low voltage would allow you to cycle states.