LUXTRONIK HEATPUMP WEBSERVICE WEB-APP for ESP32 (all variants of ESP32)

ESP32 LUXTRONIK Heatpump Controller Interface based on Websocket (for Heatpumps from alpha-inotec, Novelan, Nibe, Bosch,..) List and calculate most of the values from Luxtronik on a ESP32 Microcontroller.

(this Version has been developed and tested based on software version V3.90.4, not testet with V2.x, does not work with V1.x)

.. a wild mix of german and (in source code) english. (if it is usefull for other users there is no problem to communictate at ISSUES or PULL REQUESTS in english)

Add-Ons:

  • Tibber-Puls Adapter Integration
  • SGready (Smart-Grid-Ready Relay-Interface) with Hardware or Tasmota or Shelly Relais
  • Smart-Home-Interface (SHI) (needs firmware Luxtronik 2.1 >= V3.90.2)
  • Shelly HT3 indoor room temperatur sensor via MQTT
  • API and visualisation of EPEX-Price Data including local fix costs and tax
  • RS485 Modbus integration for DS100 Energy-Meter (needs extra hardware)

Highlights:

  • online COP calculation (actual, day and sum)
  • some extra calculation for delta temperature values
  • use HTTP-Get: '/fetch' and '/fetchmeter' for getting CSV-values to home-automation programs

todo:

  • Add webclient-protocol for temp. +/+ 5Kelvin auto/manual temp. correction based on indoor room temperature (because not possible with WebSocket communication) Update: now possible with Smart-Home-Interface !

Screenshots of Web-App

Start-Page

index

Luxtronik detail data

detai
98D8
ls

Smart-Home-Interface (MODBUS TCP)

shi

Actual Day-Ahead Price inc. fix-cost and tax (optional)

epex

View and set (manual or based on EPEX-Values) the SG-ready Interface of Heatpump (optional)

epex

View Tibber-Pulse or Tasmota SML-Meter values (optional) and DS100 Meter values (optional)

epex

Text based Config-File

epex

Link to docu config-file

Update Software and Data from Webbrowser (OTG)

epex

Documentation

Config-Data

varDEVICE_s_name=ESP_LUXTRONIK2;
varWIFI_s_mode=STA;  // AP=AccessPoint STA=Station
varWIFI_s_password=mypassword;
varWIFI_s_ssid=mySSID;

; SML Adapter (Tibber-Pulse or Tasmota SML-Meter)
varSML_s_url = 192.168.0.xx;
varSML_s_password = xxxx-xxxx;
varSML_s_user = admin;

; Luxtronik Web-Interface
varLUX_s_url=192.168.2.xx;
varLUX_s_password =00000;

; EPEX Price (inc. tax)
varEPEX_i_high = 30;
varEPEX_i_low  = 27;

varCOST_f_fix  = 17.51; fixed-price-part per kwh
varCOST_i_mwst = 19;  ; tax (MwSt)

varSG_s_rule1=00,47,1,0,FIX;
varSG_s_rule2=13,21,4,05,EPEX_LOWHOUR;
varSG_s_rule3=37,40,4,04,EPEX_LOWHOUR;

;varSG_s_rule3=15,15,2,0,FIX;
;varSG_s_rule4=01,11,1,02,EPEX_HIGHHOUR;
;varSG_s_rule5=13,23,1,02,EPEX_HIGHHOUR;
;varSG_s_rule6=13,47,2,40,EPEX_HIGHLIMIT;

; SG-ready PINS for direct relay-switch on ESP32-Borad
varSG_s_out1 = GPIO_12; 
varSG_s_out2 = GPIO_10;

; SG-ready Signals for shelly double relay
varSG_s_sg1 = http://192.168.2.25/rpc/Script.Start?id=1;
varSG_s_sg2 = http://192.168.2.25/rpc/Script.Start?id=2;
varSG_s_sg3 = http://192.168.2.25/rpc/Script.Start?id=3;
varSG_s_sg4 = http://192.168.2.25/rpc/Script.Start?id=4;


; SG-Ready Power-Limit with Smart-Meter-Interface
; only for Luxtronik > V2.90.2 
; Power in 0.1kW (10 = 1kW Limit)
varSHI_i_pcsp1 = 10;
varSHI_i_pcsp2 = 11;
varSHI_i_pcsp3 = 13;
varSHI_i_pcsp4 = 18;

Syntax for varSG_s_ruleX

this is a very powerfull rule-based syntax for setting SG-ready-Mode based on time and EPEX-Price. The higher rule overrides the lower rule if there are overlapping conditions. If you need more rules or conditions this could be easy expanded in the source-code of the 'SmartGrid' lib.

Define up to 6 (X=1..6) rules for switching Smart-Grid value 1..4

varSG_s_rule<x>=<start-hour>,<end-hour>,<SG-Ready-Mode>,<var1>,<RULE>

  • set SG-ready Mode 1..4 if rule is TRUE
Parameter value remark
start-hour 0..47 values > 24 for next day
end-hour 0..47 values > 24 for next day
SG-Ready-Mode 1..4 set 'varSG_i_sg1..4'
" " " " set 'varSHI_i_pcsp1..4
var1 0..47
RULE FIX TRUE at: start- until end-hour
RULE EPEX_HIGHLIMIT TRUE if hour-price >= var1
RULE EPEX_LOWLIMIT TRUE if hour-price <= var1
RULE EPEX_HIGHHOUR TRUE for highest-price var1 hours in start-end
RULE EPEX_LOWHOUR TRUE for lowest-price var1 hours in start-end

EPEX-price ist enduser-price inc fix-costs and all taxes

Examples:

varSG_s_rule3=0,47,1,40,EPEX_HIGHLIMIT; Set SG-Ready-Mode '1' for all EPEX-Price hours with >=40cnt from 0:00 to next Day (+47) 23:00

varSG_s_rule3=6,12,4,25,EPEX_LOWLIMIT; Set SG-Ready-Mode '4' for all EPEX-Price hours with <>=25cnt from 6:00 to 12:00

varSG_s_rule3=5,12,4,05,EPEX_LOWHOUR; SET SG-Ready-Mode '4' for the 5-hours with the lowest EPEX-price from 5:00 to 12:00

varSG_s_rule3=18,23,2,07,EPEX_HIGHHOUR; SET SG-Ready-Mode '2" for the 7-hours with the highest EPEX-price from 18:00 to 23:00